Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Terza Missione

Influence of the dental implant macrogeometry and threads design on primary stability: an in vitro simulation on artificial bone blocks

Public Engagement
The implant macrogeometry and thread profile represent one of the most important factors for a successful achievement of primary stability during the positioning procedure. The aim of the present investigation was to evaluate the insertion torque (IT), removal torque (RT) and Implant stability Quotient (ISQ) of two different implant macrogeometry and thread profile on solid rigid polyurethane model. Two different implants macrogeometries were tested: K2 (Group I) with 11° angle, 1.17 mm pitch and self-cutting V thread profile and K3 (Group II) implants with 30° angle, 0.71 mm pitch and spyral thread profile. A total of 120 specimens (n = 60 for each group) were positioned into different conditions of solid rigid polyurethane blocks. The insertion torque (IT), removal torque (RT) and ISQ were measured for each specimen. All specimens achieved the positioning into solid rigid polyurethane blocks for both of groups with no loss of stability. A significantly higher IT, RT and ISQ were detected in Group II (p < 0.05). In both groups the mean values for IT, RT and ISQ appeared promising from a clinical point of view. In spite of different macrogeometry and thread profile, both implant types achieved high primary stability on solid rigid polyurethane block to support the functional loading for a clinical application.
  • Dati Generali
  • Ricerca
  • Afferenze

Dati Generali

Tipo

02 - Tematica relativa alla produzione, gestione di beni pubblici

Strutture collegate

DIPARTIMENTO DI TECNOLOGIE INNOVATIVE IN MEDICINA & ODONTOIATRIA (Coordinatore/Organizzatore)

Ricerca

Parole chiave libere (4)

  • ascendente
  • decrescente
DENTAL IMPLANT
DRILLING
KEYWORDS: MECHANICAL BEHAVIOUR
POLYURETHANE BLOCK.
No Results Found
  • «
  • ‹
  • {pageNumber}
  • ›
  • »
{startItem} - {endItem} di {itemsNumber}

Afferenze

Referenti

LORUSSO FELICE (Organizzatore, Partecipante)

Partecipanti

LORUSSO FELICE (Organizzatore, Partecipante)
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.0.0