On the reliability of the equivalent frame models: the case study of the permanently monitored Pizzoli’s town hall
Articolo
Data di Pubblicazione:
2021
Abstract:
This paper presents the comparison of the results of modal and nonlinear analyses carried out on a 2-story masonry building with rigid diaphragms, inspired by the Pizzoli’s town hall (AQ, Italy). The case study is one of the Benchmark Structures (labeled BS6) in the “URM nonlinear modelling–Benchmark project” funded by the Italian Department of Civil Protection (DPC) within the framework of the ReLUIS projects. The building has been instrumented since 2009 with a permanent monitoring system by the Osservatorio Sismico delle Strutture (OSS) of the DPC and was hit by the 2016/2017 Central Italy earthquake sequence. In the research first phase, modal and nonlinear static analyses were carried out in a blind prediction, without any preliminary calibration of the models, but referring only to commonly made assumptions on materials and modelling. Five computer programs based on the Equivalent Frame Model (EFM) approach were used. Four different structural configurations were considered: with weak spandrels (A), with tie rods coupled to spandrels (B), with RC ring beams coupled to spandrels (C) and with “shear type” idealization (D). In the research second phase, two of the developed EFMs were calibrated in the elastic range using the results of available Ambient Vibration Tests (AVTs). The models were then validated in the nonlinear range by simulating the dynamic response of the structure recorded during the mainshocks of the 2016/2017 Central Italy earthquake. Recorded and numerical results were compared at both the global and local scale.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Benchmark; Equivalent frame modelling; Masonry; Nonlinear analysis
Elenco autori:
Degli Abbati, S.; Morandi, P.; Cattari, S.; Spacone, E.
Link alla scheda completa:
Link al Full Text:
Pubblicato in: