Accuracy of DICOM–DICOM vs. DICOM–STL Protocols in Computer-Guided Surgery: A Human Clinical Study

Articolo
Data di Pubblicazione:
2022
Abstract:
Guided implant surgery can enhance implant placement positioning, increasing predictabil-ity and decreasing postoperative complications., To date, the best protocol to be used for template realization is still unknown. Thus, the aim herein was to clinically compare the accuracy of two different protocols. A total of 48 implants were divided into Group A (24 implants), in which a stereolithographic template was realized using the digital imaging and communications in medicine (DICOM) data arrived from cone beam computer tomographies (CBCTs) (patients and prothesis alone), and Group B (24 implant), in which a standard intraoral stent with a standardized extraoral support was used for patients’ intraoral impressions and CBCT. The preimplant virtual planning and postsurgery CBCT images of both groups were superimposed, and differences were registered in terms of average deviations at the platform (a) and implant apex (b), mean depth change (c), and angular deviation (d). The results demonstrated that there were no statistically significant differences between groups (p = 0.76) for the parameters measured. However, statistically significant differences (p < 0.05) were found between maxillary and mandible implant surgery, as the latter showed greater accuracy. Additional studies are necessary to further reduce discrepancies between planning and surgical procedures.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
accuracy; CAD–CAM; dental implants; DICOM–STL; digital workflow; guided surgery; static guided surgery; stereolithographic surgical guide
Elenco autori:
D'Addazio, G.; Xhajanka, E.; Traini, T.; Santilli, M.; Rexhepi, I.; Murmura, G.; Caputi, S.; Sinjari, B.
Autori di Ateneo:
CAPUTI Sergio
D'ADDAZIO GIANMARIA
MURMURA Giovanna
SANTILLI MANLIO
SINJARI BRUNA
TRAINI TONINO
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/776534
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/776534/309050/jcm-11-02336-v2.pdf