Muscle strength, aerobic capacity, and exercise tolerance are impaired in left ventricular assist devices recipients: A pilot study
Articolo
Data di Pubblicazione:
2022
Abstract:
Background: Left ventricular assist devices (LVAD) are increasingly being used
as a therapy for advanced heart failure, both as a bridge to heart transplant and,
given the rapid advances in the LVAD’s functionality and safety, and constant
lack in availability of donor organs, as long-term destination therapy. With the
diffusion of such therapy, it is crucial to assess patients’ muscle strength, aerobic
capacity and exercise tolerance, to improve their functional capacity.
Methods: 38 LVAD recipients (33 men and five women) were included. Exercise
testing including a maximal cardiopulmonary exercise test (CPET), handgrip,
isometric and isokinetic strength testing of knee and ankle flexion/extension,
and Romberg balance test in three conditions (eyes open, eyes closed, double
task). Given the small and heterogeneous final sample size, a mostly descriptive
statistical approach was chosen.
Results: 12 participants were classified as “Obese” (BMI>29.9). The most
common comorbidities were type II diabetes and chronic kidney disease.
Only 12 participants were able to successfully complete all the assessments.
CPET and isokinetic strength trials were the least tolerated tests, and the
handgrip test the best tolerated. Mean VO2 peak was 12.38 ± 3.43 ml/kg/
min, with 15 participants below 50% of predicted VO2 max, of which
6 below 30% VO2max. Mean handgrip strength was 30.05 ± 10.61 Kg;
25 participants were below the 25° percentile of their population’s normative
reference values for handgrip strength, 10 of which were below the 5°
percentile. Issues with the management of the external pack of the LVAD
and its influence on the test limited the validity of the balance tests data,
therefore, no solid conclusions could be drawn from them. VO2 peak did not
correlate with handgrip strength or with any of the lower limb strength
measures.
Conclusion: LVAD recipients show greatly reduced functional capacity and
tolerance to exercise and exercise testing, with low overall strength levels. As
strength variables appear to be independent from VO2 peak, different lower
limbs strength tests should be explored to find a tolerable alternative in this
population, which is subjected to muscle wasting due to old age, reduced tissue
perfusion, side effects from the pharmacological therapies, and prolonged
periods of bedrest.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
left ventricular assist device, exercise test, muscle strength, exercise tolerance, aerobic
capacity, postural control
Elenco autori:
Gobbo, Stefano; Favro, Francesco; Bullo, Valentina; Cugusi, Lucia; Blasio, Andrea Di; Bortoletto, Alessandro; Bocalini, Danilo Sales; Gasperetti, Andrea; Ermolao, Andrea; Bergamin, Marco
Link alla scheda completa:
Link al Full Text:
Pubblicato in: