Fixture Length and Primary Stability: An In Vitro Study on Polyurethane Foam

Articolo
Data di Pubblicazione:
2022
Abstract:
Background: Recently, novel dental implants that are characterized by different levels of surface roughness in the distinct parts of the fixture’s body have been introduced in the market. These surface characteristics could affect the primary stability of the implants. The aim of this in vitro study was to compare the primary stability of short and long implants, characterized by multiscale surface roughness, inserted on polyurethane blocks. The secondary aim was to understand if the implant length could be a crucial factor in the decision-making in immediate or rather than delayed loading protocol in the different bone densities. (2) Methods: A total of 20 cylindrical dental implants with a diameter of 5.0 mm were tested for the lengths 6.0 mm (short implants) versus 13.0 mm (long implants) on two different solid rigid polyurethane blocks (20 and 30 PCF). The primary stability was evaluated by measuring the insertion torque value (ITV), the removal torque (RTV), and the resonance frequency analysis RFA. (3) Results: The values of ITV, RTV, and RFA showed the same trend in all measurements. Long implants showed a significantly higher primary stability on 30 PCF blocks that present mechanical properties similar to high-density bone. On the contrary, no relevant differences were found on 20 PCF blocks, which mimic trabecular bone density. (4) Conclusions: The impact of fixture length on the primary stability of implants with multiscale surface roughness is significant in 30 PCF polyurethane corresponding to higher bone density, but not in lower ones.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Insertion torque; Polyurethane foam; Primary stability; Resonance frequency
Elenco autori:
Petrini, Morena; Tumedei, Margherita; Cipollina, Alessandro; D'Ercole, Simonetta; Stella Di Carmine, Maria; Piattelli, Adriano; Re, Marco; Iezzi, Giovanna
Autori di Ateneo:
D'ERCOLE Simonetta
IEZZI GIOVANNA
PETRINI MORENA
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/796141
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/796141/350567/Petrini%20applsci%202022.pdf
Pubblicato in:
APPLIED SCIENCES
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/2076-3417/12/5/2683
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.3.0