Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

The Effect of Implant Thread’s Pitch on Primary Stability: An In Vitro Polyurethane Study with Under-Preparation and Low-Speed Drilling

Articolo
Data di Pubblicazione:
2025
Abstract:
Background: The morphology of implant threads plays a crucial role in achieving primary stability, which is essential for successful osseointegration and immediate loading of dental implants. This study aimed to evaluate how different implant thread pitches and an under-preparation drilling technique impact primary stability using an in vitro model. Methods: The study was conducted on low-density polyurethane bone models with and without cortical layers. The following three different implant thread profiles were tested: CYROTH 0.40 (0.40 mm), CYROTH 0.45 (0.45 mm), and CYROTH T (0.35 mm). Two different drilling procedures were utilized, with diameters of 3.4 mm and 3.7 mm, at a low rotational speed of 30 rpm. Primary stability was assessed by measuring insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA). Results: The low rotational speed of 30 rpm was found to be effective for achieving favorable fixation parameters in all scenarios. The 0.45 mm thread consistently exhibited higher implant stability quotient (ISQ) values (from two to six points higher) compared to the 0.40 mm and standard 0.35 mm threads, while also requiring lower IT. The highest ISQ values were recorded in the 20 pounds per cubic foot (PCF) block with a cortical layer using the 0.45 mm thread and a 3.4 mm drill. The under-preparation using the 3.4 mm drill resulted in higher IT and RT values than the 3.7 mm drill. Conclusions: This study demonstrated that implant thread pitch and drilling technique are critical factors influencing primary stability. Utilizing a wider thread pitch (0.45 mm) along with an under-preparation drilling protocol can significantly improve implant stability, even in low-density bone, without the need for excessive IT. These findings suggest that selecting the appropriate implant macrogeometry and surgical technique can optimize the primary stability of dental implants.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
dental implant; drill osteotomy; osseointegration; primary stability
Elenco autori:
Tumedei, Margherita; Di Pietro, Natalia; Romasco, Tea; Piattelli, Adriano; Comuzzi, Luca
Autori di Ateneo:
DI PIETRO NATALIA
ROMASCO TEA
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/867134
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/867134/565014/Tumedei_applsci-15-11245.pdf
Pubblicato in:
APPLIED SCIENCES
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/2076-3417/15/20/11245
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.3.0