Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Development of implant/interconnected porous hydroxyapatite complex as new concept graft material.

Articolo
Data di Pubblicazione:
2012
Abstract:
BACKGROUND: Dental implant has been successfully used to replace missing teeth. However, in some clinical situations, implant placement may be difficult because of a large bone defect. We designed novel complex biomaterial to simultaneously restore bone and place implant. This complex was incorporated implant into interconnected porous calcium hydroxyapatite (IP-CHA). We then tested this Implant/IP-CHA complex and evaluated its effect on subsequent bone regeneration and implant stability in vivo. METHODOLOGY/PRINCIPAL FINDINGS: A cylinder-type IP-CHA was used in this study. After forming inside of the cylinder, an implant was placed inside to fabricate the Implant/IP-CHA complex. This complex was then placed into the prepared bone socket in the femur of four beagle-Labrador hybrid dogs. As a control, implants were placed directly into the femur without any bone substrate. Bone sockets were allowed to heal for 2, 3 and 6 months and implant stability quotients (ISQ) were measured. Finally, tissue blocks containing the Implant/IP-CHA complexes were harvested. Specimens were processed for histology and stained with toluidine blue and bone implant contact (BIC) was measured. The ISQs of complex groups was 77.8±2.9 in the 6-month, 72.0±5.7 in the 3-month and 47.4±11.0 in the 2-month. There was no significant difference between the 3- or 6-month complex groups and implant control groups. In the 2-month group, connective tissue, including capillary angiogenesis, was predominant around the implants, although newly formed bone could also be observed. While, in the 3 and 6-month groups, newly formed bone could be seen in contact to most of the implant surface. The BICs of complex groups was 2.18±3.77 in the 2-month, 44.03±29.58 in the 3-month, and 51.23±8.25 in the 6-month. Significant difference was detected between the 2 and 6-month. CONCLUSIONS/SIGNIFICANCE: Within the results of this study, the IP-CHA/implant complex might be able to achieve both bone reconstruction and implant stability.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
RESONANCE FREQUENCY-ANALYSIS; INITIAL BONE REGENERATION; CALCIUM HYDROXYAPATITE; INORGANIC POLYPHOSPHATE; BLOCK HYDROXYAPATITE; IMPLANT STABILITY; AUTOGENOUS BONE; ARTIFICIAL BONE; DENTAL IMPLANTS; OSSEOINTEGRATION
Elenco autori:
Doi, K; Oue, H; Morita, K; Kajihara, S; Kubo, T; Koretake, K; Perrotti, Vittoria; Iezzi, Giovanna; Piattelli, Adriano; Akagawa, Y.
Autori di Ateneo:
IEZZI GIOVANNA
PERROTTI Vittoria
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/381487
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/381487/8255/DEVELOPMENT%20OF%20IMPLANT%20INTERCONNECTED%20POROUS%20HA%20COMPLEX%20%20%20PLOS%20ONE.pdf
Pubblicato in:
PLOS ONE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.5.3.0