Primary stability of dental implants in low-density (10 and 20 pcf) polyurethane foam blocks: Conical vs cylindrical implants

Academic Article
Publication Date:
2020
abstract:
Background: The aim of the present study was to compare, in low-density polyurethane blocks, the primary implant stability values (micromobility) and removal torque values of three different implant geometries in two different bone densities representing the structure of the human posterior jaws. Methods: A total of 60 implants were used in the present investigation: Twenty implants for each of three groups (group A, group B, and group C), in both polyurethane 10 pcf and 20 pcf densities. The insertion torque, pull-out torque, and implant stability quotient (ISQ) values were obtained. Results: No differences were found in the values of Group A and Group B implants. In both these groups, the insertion torques were quite low in the 10 pcf blocks. Better results were found in the 20 pcf blocks, which showed very good stability of the implants. The pull-out values were slightly lower than the insertion torque values. High ISQ values were found in Group A and B implants. Lower values were present in Group C implants. Conclusions: The present investigation evaluated implants with different geometries that are available on the market, and not experimental implants specifically created for the study. The authors aimed to simulate real clinical conditions (poor-density bone or immediate post-extraction implants) in which knowledge of dental implant features, which may be useful in increasing the primary stability, may help the oral surgeon during the surgery planning.
Iris type:
1.1 Articolo in rivista
Keywords:
Bone density; Conical implants; Cylindrical implants; Implant stability quotient; Insertion and pull-out torque; Polyurethane foam blocks; Primary stability
List of contributors:
Comuzzi, L.; Tumedei, M.; Pontes, A. E.; Piattelli, A.; Iezzi, G.
Authors of the University:
IEZZI GIOVANNA
Handle:
https://ricerca.unich.it/handle/11564/722816
Full Text:
https://ricerca.unich.it//retrieve/handle/11564/722816/194588/PRYMARY%20STABILITY.pdf
Published in:
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
Journal
  • Overview

Overview

URL

https://www.mdpi.com/1660-4601/17/8/2617
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.3.5.1