Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills
  1. Outputs

Mechanical Behaviour and Primary Stability of a Self-Condensing Implant: A Laboratory Critical Simulation of a Severe Maxillary Atrophy on Polyurethane Lamina

Academic Article
Publication Date:
2022
abstract:
Background: Posterior maxillary atrophies could emerge after the loss of teeth, trauma, infections, or lesions that often require regenerative approaches. In these critical conditions, the achievement of implant primary stability represents a clinical challenge in the operative practice. Therefore, a two-stage approach is often preferred with a delay of the rehabilitation time and a consistent increasing of the biological and the operative costs. The aim of this study was to evaluate the mechanical behaviour of a self-condenser implant compared to a standard implant in a critical simulation on different thicknesses and densities of polyurethane lamina. Materials and methods: A total of two implant models were tested: a self-condensing device (test) and a standard implant (control). The study evaluated the insertion torque and the pull-out strength values of the test and control implants inserted in different sizes (1, 2, and 3 mm) and density polyurethane lamina (10, 20, and 30 pcf) for a total of 320 experimental sites. Results: In total, 320 experimental sites were produced in the polyurethane samples. A statistically significant difference of insertion and pull-out torque values between the test and control Implants was found in the different bone densities (p < 0.05). The insertion and pull-out torque values were always higher for the test implants in all experimental conditions. In all bone densities, the insertion torque values were higher than the pull-out torque values. The self-condenser dental implant design evaluated in this in vitro study showed a high level of stability in all experimental conditions. Conclusions: The test implant could represent a useful tool for a one-stage surgical approach in the presence of limited residual native bone as an alternative to a delayed technique.
Iris type:
1.1 Articolo in rivista
Keywords:
Dental implant; Laboratory simulation; Maxillary atrophies; Primary stability
List of contributors:
Comuzzi, L.; Iezzi, G.; Lucchese, A.; Di Pietro, N.; Balice, P.; D'Arcangelo, C.; Piattelli, A.; Tumedei, M.
Authors of the University:
D'ARCANGELO Camillo
DI PIETRO NATALIA
IEZZI GIOVANNA
Handle:
https://ricerca.unich.it/handle/11564/776274
Full Text:
https://ricerca.unich.it//retrieve/handle/11564/776274/308589/Comuzzi%20and%20Di%20Pietro%20et%20al%20Appl%20Sc%202022.pdf
Published in:
APPLIED SCIENCES
Journal
  • Overview

Overview

URL

https://www.mdpi.com/2076-3417/12/3/966
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.3.0