Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills
  1. Outputs

Clinical and Radiological Evaluation of a Self-Condensing Bone Implant in One-Stage Sinus Augmentation: A 3-Year Follow-Up Retrospective Study

Academic Article
Publication Date:
2023
abstract:
: Stabilization of dental implants in the sinus region with a bone height below 4 mm gen-erally requires a two-stage sinus floor elevation surgery. To improve this aspect, the aim of this retrospective study was to demonstrate the feasibility of performing a one-stage maxillary sinus augmentation using an innovative self-condensing implant design, even in case of a bone height close to 2 mm. Clinical and radiological outcomes from 54 patients (26 females; 28 males; 69 total implants positioned) were analyzed 3 years post-surgery. The three-dimensional grafts change was evaluated by Cone-Beam Computed Tomography (CBCT) before surgery (T0), immediately after surgery (T1), and 1-year post-surgery (T2). The sinus floor levels measured at the medial (M-W), middle (MD-W), and lateral (L-W) walls reported: M-W of 1.9 ± 2.4 mm (T1) and 1.7 ± 2.6 mm (T2); MD-W of -0.1 ± 2.7 mm (T1) and 0.7 ± 2.4 mm (T2); L-W of 3.1 ± 3.0 mm (T1) and 3.1 ± 3.0 mm (T2); besides a bone crest height (C-F) of 4.6 ± 2.0 mm (T1) and 12.1 ± 1.4 mm (T2). Moreover, after 3 years only 1 implant was lost, and so an implant survival rate of 98.55% was recorded. In conclusion, these results suggest the efficacy of using this implant design for a one-stage sinus lift approach, not only in terms of increased implant survival rate and decreased marginal bone loss, but also for its potential applicability in case of reduced bone height.
Iris type:
1.1 Articolo in rivista
Keywords:
biomaterial; cone-beam computed tomography; maxillary sinus augmentation; one-stage sinus augmentation; self-condensing implants; xenografts
List of contributors:
Comuzzi, Luca; Tumedei, Margherita; Petrini, Morena; Romasco, Tea; Lorusso, Felice; De Angelis, Francesco; Piattelli, Adriano; Tatullo, Marco; Di Pietro, Natalia
Authors of the University:
DE ANGELIS FRANCESCO
DI PIETRO NATALIA
LORUSSO FELICE
PETRINI MORENA
ROMASCO TEA
Handle:
https://ricerca.unich.it/handle/11564/800519
Full Text:
https://ricerca.unich.it//retrieve/handle/11564/800519/360577/Comuzzi%20&%20Tumedei%20IJERPH%202023.pdf
Published in:
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.3.5.1