Method validation and hyphenated techniques: recent trends and future perspectives

Chapter
Publication Date:
2017
abstract:
The recent applications of HPLC in bioanalytical chemistry provided the development of sensitive, selective and robust methods. All these procedures require validation to obtain reproducible analysis and analyze samples. The main international regulatory agencies, e.g., Food and Drug Administration (FDA), European Medicine Agency (EMA), and Agência Nacional de Vigilância Sanitária (ANVISA) edit three level of references for Guidelines setting up the basic parameters to validate bioanalytical assays. None of them covers the validation process successfully because the matrix effect (ME) is sometimes missed or partially included in the regulatory documents. In fact, the ME can affect the quality of results and still represents the “Achilles heel” in bioanalytical chemistry using the hyphenated techniques.
Actually, several papers report the potential drawbacks of ME, and provide suitable strategies to suppress this phenomenon. Furthermore, different factors, e.g., the co-precipitation of biological samples, interfaces, chromatography and spectrometric conditions, can affect the bioanalytical assays and validation processes at different steps.
This chapter discusses the potential strategies to suppress the ME and highlights the importance of validation process according to International Guidelines. In this attempt, the best solution should be the combination of on-line techniques miniaturized systems, new ionisation sources, chemometrics approach, high performance liquid chromatography based and hyphenated techniques.
Iris type:
2.1 Contributo in volume (Capitolo o Saggio)
Keywords:
validation procedure, international guidelines, matrix effects, hyphenated techiques, bioanalytical methods, chromatographic assay, instrument configurations
List of contributors:
Locatelli, Marcello; Cifelli, R.; Vitalei, S.; Santini, P.; De Luca, E.; Bellagamba, G; Celia, Christian; Carradori, Simone; DI MARZIO, Luisa; Mollica, Adriano
Authors of the University:
CARRADORI SIMONE
CELIA Christian
DI MARZIO Luisa
LOCATELLI Marcello
MOLLICA ADRIANO
Handle:
https://ricerca.unich.it/handle/11564/671153
Book title:
Analytical Chemistry: Developments, Applications and Challenges in food analysis
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.9.2.0