Accuracy of DICOM-DICOM vs. DICOM-STL Protocols in Computer-Guided Surgery: A Human Clinical Study

Public Engagement
Guided implant surgery can enhance implant placement positioning, increasing predictability and decreasing postoperative complications., To date, the best protocol to be used for template realization is still unknown. Thus, the aim herein was to clinically compare the accuracy of two different protocols. A total of 48 implants were divided into Group A (24 implants), in which a stereolithographic template was realized using the digital imaging and communications in medicine (DICOM) data arrived from cone beam computer tomographies (CBCTs) (patients and prothesis alone), and Group B (24 implant), in which a standard intraoral stent with a standardized extraoral support was used for patients’ intraoral impressions and CBCT. The preimplant virtual planning and postsurgery CBCT images of both groups were superimposed, and differences were registered in terms of average deviations at the platform (a) and implant apex (b), mean depth change (c), and angular deviation (d). The results demonstrated that there were no statistically significant differences between groups (p = 0.76) for the parameters measured. However, statistically significant differences (p < 0.05) were found between maxillary and mandible implant surgery, as the latter showed greater accuracy. Additional studies are necessary to further reduce discrepancies between planning and surgical procedures.
  • Dati Generali
  • Ricerca
  • Afferenze

Dati Generali

Tipo

02 - Tematica relativa alla produzione, gestione di beni pubblici

Strutture collegate

DIPARTIMENTO DI TECNOLOGIE INNOVATIVE IN MEDICINA & ODONTOIATRIA (Coordinatore/Organizzatore)

Ricerca

Settori


Goal 3: Good health and well-being

Parole chiave libere (8)

  • ascendente
  • decrescente
ACCURACY
CAD CAM
DENTAL IMPLANTS
DICOM STL
DIGITAL WORKFLOW
GUIDED SURGERY
STATIC GUIDED SURGERY
STEREOLITHOGRAPHIC SURGICAL GUIDE
No Results Found
  • «
  • ‹
  • {pageNumber}
  • ›
  • »
{startItem} - {endItem} di {itemsNumber}

Afferenze

Referenti

SINJARI BRUNA (Organizzatore, Partecipante)

Partecipanti (5)

CAPUTI Sergio (Partecipante)
D'ADDAZIO GIANMARIA (Partecipante)
MURMURA Giovanna (Partecipante)
SINJARI BRUNA (Organizzatore, Partecipante)
TRAINI TONINO (Partecipante)
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.0.0