Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Clinical and Radiological Evaluation of a Self-Condensing Bone Implant in One-Stage Sinus Augmentation: A 3-Year Follow-Up Retrospective Study.

Public Engagement
Stabilization of dental implants in the sinus region with a bone height below 4 mm gen-erally requires a two-stage sinus floor elevation surgery. To improve this aspect, the aim of this retrospective study was to demonstrate the feasibility of performing a one-stage maxillary sinus augmentation using an innovative self-condensing implant design, even in case of a bone height close to 2 mm. Clinical and radiological outcomes from 54 patients (26 females; 28 males; 69 total implants positioned) were analyzed 3 years post-surgery. The three-dimensional grafts change was evaluated by Cone-Beam Computed Tomography (CBCT) before surgery (T0), immediately after surgery (T1), and 1-year post-surgery (T2). The sinus floor levels measured at the medial (M-W), middle (MD-W), and lateral (L-W) walls reported: M-W of 1.9 ± 2.4 mm (T1) and 1.7 ± 2.6 mm (T2); MD-W of -0.1 ± 2.7 mm (T1) and 0.7 ± 2.4 mm (T2); L-W of 3.1 ± 3.0 mm (T1) and 3.1 ± 3.0 mm (T2); besides a bone crest height (C-F) of 4.6 ± 2.0 mm (T1) and 12.1 ± 1.4 mm (T2). Moreover, after 3 years only 1 implant was lost, and so an implant survival rate of 98.55% was recorded. In conclusion, these results suggest the efficacy of using this implant design for a one-stage sinus lift approach, not only in terms of increased implant survival rate and decreased marginal bone loss, but also for its potential applicability in case of reduced bone height.
  • Dati Generali
  • Ricerca
  • Afferenze

Dati Generali

Tipo

02 - Tematica relativa alla produzione, gestione di beni pubblici

Strutture collegate

DIPARTIMENTO DI TECNOLOGIE INNOVATIVE IN MEDICINA & ODONTOIATRIA (Coordinatore/Organizzatore)

Ricerca

Parole chiave libere (6)

  • ascendente
  • decrescente
CONE-BEAM COMPUTED TOMOGRAPHY
KEYWORDS: BIOMATERIAL
MAXILLARY SINUS AUGMENTATION
ONE-STAGE SINUS AUGMENTATION
SELF-CONDENSING IMPLANTS
XENOGRAFTS.
No Results Found
  • «
  • ‹
  • {pageNumber}
  • ›
  • »
{startItem} - {endItem} di {itemsNumber}

Afferenze

Referenti

LORUSSO FELICE (Organizzatore, Partecipante)

Partecipanti

LORUSSO FELICE (Organizzatore, Partecipante)
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.6.0.0