Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Aliased Flow Signal Planimetry by Cardiovascular Magnetic Resonance Imaging for Grading Aortic Stenosis Severity: A Prospective Pilot Study

Articolo
Data di Pubblicazione:
2021
Abstract:
Objectives: Transthoracic echocardiography (TTE) is the standard technique for assessing aortic stenosis (AS), with effective orifice area (EOA) recommended for grading severity. EOA is operator-dependent, influenced by a number of pitfalls and requires multiple measurements introducing independent and random sources of error. We tested the diagnostic accuracy and precision of aliased orifice area planimetry (AOAcmr), a new, simple, non-invasive technique for grading of AS severity by low-VENC phase-contrast cardiovascular magnetic resonance (CMR) imaging. Methods: Twenty-two consecutive patients with mild, moderate, or severe AS and six age- and sex-matched healthy controls had TTE and CMR examinations on the same day. We performed analysis of agreement and correlation among (i) AOAcmr; (ii) geometric orifice area (GOAcmr) by direct CMR planimetry; (iii) EOAecho by TTE-continuity equation; and (iv) the "gold standard" multimodality EOA (EOAhybrid) obtained by substituting CMR LVOT area into Doppler continuity equation. Results: There was excellent pairwise positive linear correlation among AOAcmr, EOAhybrid, GOAcmr, and EOAecho (p < 0.001); AOAcmr had the highest correlation with EOAhybrid (R 2 = 0.985, p < 0.001). There was good agreement between methods, with the lowest bias (0.019) for the comparison between AOAcmr and EOAhybrid. AOAcmr yielded excellent intra- and inter-rater reliability (intraclass correlation coefficient: 0.997 and 0.998, respectively). Conclusions: Aliased orifice area planimetry by 2D phase contrast imaging is a simple, reproducible, accurate "one-stop shop" CMR method for grading AS, potentially useful when echocardiographic severity assessment is inconclusive or discordant. Larger studies are warranted to confirm and validate these promising preliminary results.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
CMR; aliasing analysis; aortic stenosis (AS); echocardiography; phase contrast (PC); valvular heart disease
Elenco autori:
Mantini, Cesare; Khanji, Mohammed Y; D'Ugo, Emilia; Olivieri, Marzia; Caputi, Cristiano Giovanni; Bufano, Gabriella; Mastrodicasa, Domenico; Calvo Garcia, Darien; Rotondo, Domenico; Candeloro, Matteo; Tana, Claudio; Cademartiri, Filippo; Ionescu, Adrian; Caulo, Massimo; Gallina, Sabina; Ricci, Fabrizio
Autori di Ateneo:
CALVO GARCIA Darien
CANDELORO MATTEO
CAULO MASSIMO
GALLINA Sabina
MANTINI CESARE
RICCI FABRIZIO
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/762246
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/762246/280943/Mantini_FCVM%202021.pdf
Pubblicato in:
FRONTIERS IN CARDIOVASCULAR MEDICINE
Journal
  • Dati Generali

Dati Generali

URL

https://www.frontiersin.org/articles/10.3389/fcvm.2021.752340/full
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.7.2.0