Skip to Main Content (Press Enter)

Logo UNICH
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNICH

|

UNI-FIND

unich.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Collagen Fibres Orientation in the Bone Matrix around Dental Implants: Does the Implant's Thread Design Play a Role?

Articolo
Data di Pubblicazione:
2021
Abstract:
The aim of this study was to analyse the influence of different thread shapes of titanium dental implant on the bone collagen fibre orientation (BCFO) around loaded implants. Twenty titanium dental implants, divided for thread shapes in six groups (A–F) were analysed in the present study. All implants were immediately loaded and left in function for 6 months before retrieval. The parameters evaluated under scanning electron microscope were the thread width, thread depth, top radius of curvature, flank angle, and the inter-thread straight section. Two undecalcified histological sections were prepared from each implant. Birefringence analysis using circularly polarized light microscopy was used to quantitively measure BCFO. For groups A–F, respectively, transverse BCFO was 32.7%, 24.1%, 22.3%, 18.2%, 32.4%, and 21.2%, longitudinal BCFO was 28.2%, 14.5%, 44.9%, 33.1%, 37.7%, and 40.2%. The percentage differences between transverse and longitudinal orientation were 4.50% (A), 9.60% (B), −22.60% (C), −14.90% (D), −5.30% (E), and −19.00% (F). Following loading, the amount of transverse and longitudinal BCFO were significantly influenced by the thread shape. The greater flank angles and narrower inter-thread sections of the “V” shaped and “concave” shaped implant threads of groups A and B, respectively, promoted the predominance of transverse BCFO, compared to groups C-F (p < 0.05). A narrow inter-thread straight section promotes transverse BCFO, as do “V” shaped and “concave” shaped threads, which can thus be considered desirable design for implant threads.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Birefrin-gence analysis; Circularly polarized light; Collagen fibres orientation; Dental implant; Immediate loading; Thread shape; Fibrillar Collagens; Humans; Jaw; Dental Implants; Osseointegration; Prosthesis Design
Elenco autori:
Valente, F.; Scarano, A.; Murmura, G.; Varvara, G.; Sinjari, B.; Mandelli, F.; Piattelli, M.; Caputi, S.; Traini, T.
Autori di Ateneo:
CAPUTI Sergio
MURMURA Giovanna
SCARANO Antonio
SINJARI BRUNA
TRAINI TONINO
VARVARA GIUSEPPE
Link alla scheda completa:
https://ricerca.unich.it/handle/11564/771001
Link al Full Text:
https://ricerca.unich.it//retrieve/handle/11564/771001/298444/ijms-22-07860.pdf
Pubblicato in:
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES
Journal
  • Dati Generali

Dati Generali

URL

https://www.mdpi.com/1422-0067/22/15/7860
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.5.0