Maxillary sinus augmentation with a porous synthetic hydroxyapatite and bovine-derived hydroxyapatite: a comparative clinical and histologic study.
Articolo
Data di Pubblicazione:
2007
Abstract:
Purpose: The aim of this study was to determine the clinical and histologic results of a porous synthetic
hydroxyapatite (HA) compared with bovine-derived HA used in maxillary sinus augmentation.
Materials and Methods: A total of 100 titanium implants were placed in 40 patients. Patients in need
of maxillary sinus augmentation were divided into 2 groups. Group 1 received bovine-derived HA (20
patients with 50 implants), while group 2 received a porous synthetic HA (20 patients with 50
implants). After a healing period of 6 months, second-stage surgery was carried out. In 50 cases (25
from group 1 and 25 from group 2), bone cores were harvested from grafted areas and processed for
histologic examination. Results: Four implants that failed to osseointegrate were removed at the second-
stage surgery (2 from a patient from group 1, and 2 from a patient from group 2). All patients were
followed for at least 1 year after loading. Histologically, most of the HA particles from both groups were
surrounded by newly formed bone. No statistically significant differences were found with respect to
percentage of newly formed bone between the 2 groups (P = .031); however, the groups did differ significantly
with respect to the percentage of residual graft material observed (P = .001). Conclusion:
This study demonstrates that both bovine-derived and porous synthetic HA can be used successfully
as graft materials for maxillary sinus augmentation. The clinical performance of the 2 materials was
similar.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Mangano, C; Scarano, Antonio; Perrotti, Vittoria; Iezzi, Giovanna; Piattelli, Adriano
Link alla scheda completa:
Pubblicato in: